(At thecontroller & devices)
(At the cable)
50 PIN CENTRONICS FEMALE at the controller & devices.
50 PIN CENTRONICS MALE at the cable.
Pin | Name | Dir | Description |
---|---|---|---|
01 | GND | ![]() | Ground |
02 | +DB0 | ![]() | +Data Bus 0 |
03 | +DB1 | ![]() | +Data Bus 1 |
04 | +DB2 | ![]() | +Data Bus 2 |
05 | +DB3 | ![]() | +Data Bus 3 |
06 | +DB4 | ![]() | +Data Bus 4 |
07 | +DB5 | ![]() | +Data Bus 5 |
08 | +DB6 | ![]() | +Data Bus 6 |
09 | +DB7 | ![]() | +Data Bus 7 |
10 | +DBP | ![]() | +Data Bus Parity (odd Parity) |
11 | DIFFSENS | ? | ??? |
12 | res | - | Reserved |
13 | TERMPWR | ![]() | Termination Power |
14 | res | - | Reserved |
15 | +ATN | ![]() | +Attention |
16 | GND | ![]() | Ground |
17 | +BSY | ![]() | +Bus is busy |
18 | +ACK | ![]() | +Acknowledge |
19 | +RST | ![]() | +Reset |
20 | +MSG | ![]() | +Message |
21 | +SEL | ![]() | +Select |
22 | +C/D | ![]() | +Control or Data |
23 | +REQ | ![]() | +Request |
24 | +I/O | ![]() | +In/Out |
25 | GND | ![]() | Ground |
26 | GND | ![]() | Ground |
27 | -DB0 | ![]() | -Data Bus 0 |
28 | -DB1 | ![]() | -Data Bus 1 |
29 | -DB2 | ![]() | -Data Bus 2 |
30 | -DB3 | ![]() | -Data Bus 3 |
31 | -DB4 | ![]() | -Data Bus 4 |
32 | -DB5 | ![]() | -Data Bus 5 |
33 | -DB6 | ![]() | -Data Bus 6 |
34 | -DB7 | ![]() | -Data Bus Pariy7 |
35 | -DBP | ![]() | -Data Bus Pariy (odd Parity) |
36 | GND | ![]() | Ground |
37 | res | - | Reserved |
38 | TERMPWR | ![]() | Termination Power |
39 | res | - | Reserved |
40 | -ATN | ![]() | -Attention |
41 | GND | ![]() | Ground |
42 | -BSY | ![]() | -Bus is busy |
43 | -ACK | ![]() | -Acknowledge |
44 | -RST | ![]() | -Reset |
45 | -MSG | ![]() | -Message |
46 | -SEL | ![]() | -Select |
47 | -C/D | ![]() | -Control or Data |
48 | -REQ | ![]() | -Request |
49 | -I/O | ![]() | -In/Out |
50 | GND | ![]() | Ground |